MastCurr Series-MC003
MC003E1-A2
> Meets the residual-current test requirements for Mode 2 charging under IEC 62752
> Meets the residual-current test requirements for RDC-PD in Mode 3 charging under IEC 62955
> Meets the basic requirements of GB/T 22794 and supports DC 6 mA testing requirements
|
Waveform |
Frequency |
Minimum |
Typical |
Maximum |
Unit |
|
AC |
50Hz |
20.0 |
22.8 |
26.0 |
mA |
|
A0° |
50Hz |
11.0 |
15.0 |
30.0 |
mA |
|
A90° |
50Hz |
10.0 |
20.0 |
30.0 |
mA |
|
A135° |
50Hz |
10.0 |
24.0 |
35.0 |
mA |
|
2PDC |
- |
3.5 |
5.0 |
7.0 |
mA |
|
3PDC |
- |
3.1 |
4.6 |
6.2 |
mA |
|
S-DC |
- |
3.0 |
4.6 |
6.0 |
mA |
|
F |
- |
27.0 |
33.0 |
38.0 |
mA |
|
Waveform |
Frequency |
Current Magnitude |
Typical |
Unit |
|
AC |
50Hz |
30mA |
25 |
ms |
|
AC |
50Hz |
60mA |
17 |
ms |
|
AC |
50Hz |
150mA |
13 |
ms |
|
AC |
50Hz |
5A~100A |
10 |
ms |
|
A0° |
50Hz |
42mA |
17 |
ms |
|
A0° |
50Hz |
84mA |
13 |
ms |
|
A0° |
50Hz |
210mA |
13 |
ms |
|
A0° |
50Hz |
42mA+6mADC |
17 |
ms |
|
A0° |
50Hz |
84mA+6mADC |
13 |
ms |
|
A0° |
50Hz |
210mA+6mADC |
13 |
ms |
|
S-DC |
- |
6mA |
50 |
ms |
|
S-DC/3PDC |
- |
60mA |
15 |
ms |
|
S-DC/3PDC |
- |
300mA |
10 |
ms |
|
2PDC |
- |
60mA |
20 |
ms |
|
2PDC |
- |
300mA |
13 |
ms |
|
F |
- |
210mA |
13 |
ms |
|
Parameter |
Specification |
|
Operating Ambient Temperature |
-40℃~105 ℃ |
|
Storage Temperature |
-40℃~105 ℃ |
|
Operating Humidity |
≤95% |
|
Operating Voltage (VDD)(1) |
4.85~5.15 VDC |
|
Power Consumption |
≤110mW |
|
Voltage Input/Output, Low Level |
0~0.6VDC |
|
Voltage Input/Output, High Level |
4.2~5VDC |
|
FIT(2) |
25℃ = 19 85℃ = 166 |
|
Design Life(3) |
≥ 20 years |
|
Operating Altitude(4) |
≤ 4000m |
(1) To achieve better performance, the supply voltage should be maintained at 4.90~5.10 VDC.
(2) The FIT value is calculated in accordance with the relevant provisions of IEC 61709 using the FIT values provided for the individual BoM components. The FIT value is calculated for ground mobile equipment compliant with IEC 61709 in an environment free of dust and harmful substances. Please contact us if you have special requirements.
(3) The stated product design life is based on the mean time between failures (MTBF) calculated in accordance with IEC 61709.
(4) Altitude-related calculations are based on the clearance and creepage-distance requirements calculated under the following conditions: reinforced insulation, pollution degree 2, material group 1, and overvoltage category 2.
We may improve the content of this page or make necessary corrections to errors or inaccuracies at any time due to technical upgrades or the adoption of updated production processes, without prior notice. When placing an order, customers should contact the company to verify the relevant information.